      Select micro-pump

      pressure unit conversion table

      GminiP Series of micro-Pump £¨Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (mL/min)

      Weight

      (g)

      Pump Size

      Detailed Structure of the show

      reference Appearance

      GminiPA-1

      3.5

      30-50

      35

      -25

      800

      16

      16¡Á24¡Á31

      >>here

      GminiPA-2

      3.5

      30-40

      35

      -20

      300

      16

      16¡Á24¡Á31

      >>here

      Ibid

      pressure unit conversion table

      GminiP Series of micro-Pump £¨Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (mL/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Detailed Structure of the show

      reference Appearance

      GminiPB-1

      3.5

      100

      35

      -25

      800

      28

      16¡Á24¡Á41

      >>here

      GminiPB-2

      3.5

      100

      35

      -20

      300

      28

      16¡Á24¡Á41

      >>here

      Ibid

      GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa £¨Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPA-1

      1.5-5

      test:4V

      ¡Ö40-100

      50

      20-30

      0.3-1.5

      35

      40¡Á23¡Á36

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPA-2

      2.0-5

      test:4V

      ¡Ö30-100

      50

      30-40

      0.5-2.0

      35

      40¡Á23¡Á36

      Ibid

      Ibid

      GMPA-3

      3-6

      ¡Ö40-70

      50

      20-30

      0.5-1.5

      35

      40¡Á23¡Á36

      Ibid

      Ibid

      GMPA-4

      3-6

      ¡Ö50-90

      50

      30-40

      0.5-1.8

      35

      40¡Á23¡Á36

      Ibid

      Ibid

      ¡¡

      GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .£¨suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump £©

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPC-1/2/3

      6/9/12

      <200/120/90

      >100

      50-65

      2.5-3

      45

      50¡Á22¡Á31

      ¡¡

      Structure>>here

      flow-load diagram

      voltage-flow chart

      GMPC-4/5/6

      6/9/12

      <150/110/80

      >80

      50-55

      2.0-2.5

      45

      50¡Á22¡Á31 ibid

      ibid

      GMPD Series of micro-pump£¨suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump £©with special needs can be put on a positive pressure above 0.1mpa .

      Name and model

      Voltage

      (V)

      No-load Current

      (mA)

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      (L/min)

      Weight

      (g)

      Pump Size

      Installation instructions

      Structure of the show

      reference Figure

      GMPD-1/2/3

      6/12/24

      <230/130/80

      60-100

      60

      3-8

      82

      35¡Á44.5¡Á56.5

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPD-4/5/6

      6/12/24

      <200/100/60

      60-100

      50

      3-7

      82

      35¡Á44.5¡Á56.5 ibid

      ibid

      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

      GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

      Name and model

      Voltage

      (V)

      No-load Current

      £¨mA£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPE-1/2

      12/24

      <180/90

      60

      50-55

      3-6

      149

      335¡Á43.5¡Á72

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GMPE-3/4/-

      12/24 ¡¡ -20-40 Custom 3L¡¢4L¡¢5L 149 35¡Á43.5¡Á72

      Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

      GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPF25-1/2

      12/24 0.6/.3 >100 -70 25 480 86¡Á56.5¡Á126

      ¡¡

      Structure>>here

      GMPF15-3/4

      12/24 0.6/0.3 >60 -50 18 480 86¡Á56.5¡Á126

      Structure>>here

      ¡¡

      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GMPG-1/2

      6-12/24

      <0.450

      100

      20-50

      36

      620

      86¡Á70¡Á126

      ¡¡

      Structure>>here

      GMPG-3/4

      6-9/24

      <0.550

      100

      20-50

      36

      620

      86¡Á70¡Á126 ¡¡

      ibid

      GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

      ¡¡

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPB-1/2

      6/12

      <0.25/0.135

      ¡¡

      ¡¡

      100

      series260

      ¡¡

      -45-55

      series vacum

       -85

      single:2¡Á2

      dual:2.8

      55

      24¡Á47¡Á49

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GDMPB-3/4

      6/12¡¡

      <0.25/0.135

      ¡¡

      100

      series260

      50-65

      single:2.5¡Á2

      dual:3.8

      55

      24¡Á47¡Á49

      ¡¡

      ibid

      GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPC-1/2

      12/24

      <0.135/0.08

      100

      series260

      -45-55

      series vacum

      -75

      single

      2¡Á2L/min

      dual

      2.8L/min

      75

      24¡Á47¡Á51

      flow-load diagram

      voltage-flow chart

      Structure>>here

      GDMPC-3/4

      12/24

      <0.135/0.08

      ¡¡

      series

      260

      -50-65

      series vacum

      -80

      single:2.5¡Á2

      dual:3.8

      5

      24¡Á47¡Á51 ¡¡

      ibid

      ¡¡

      GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨mA£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPD-1/2

      12/24

      <200

      /135

      100

      -40-50

      series vacum

      -75

      single:7¡Á2

      dual:10

      107

      35¡Á48¡Á55.5 ¡¡

      GDMPD-3/4

      12/24

      <240

      /135

      100

      -40-60

      series vacum

      -80

      single:8¡Á2

      dual:11

      107

      35¡Á48¡Á55.5 ¡¡ ¡¡

      GDMPD-5/6

      12/24

      <180

      /115

      100

      -35-45

      single:5¡Á2

      dual:8

      107

      35¡Á48¡Á55.5 ¡¡ ¡¡
      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

      Name and model

      Voltage

      (V)

      No-load Current

      £¨mA£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPE-1/2

      12/24

      <180/100

      100

      -40-50

      series vacum

      -75

      single:6¡Á2

      dual:10

      175

      35¡Á48¡Á71.5

      flow-load diagram

      voltage-flow chart

      Structure>>here

      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPF(40)-1/2

      12/24

      ¡Ö0.80

      100

      20-60

      single:28¡Á2

      dual:40

      618

      10¡Á56.5¡Á126

      voltage-flow chart

      Structure>>here

      GDMPF(25)-3/4

      12/24

      ¡¡

      ¡Ö0.70

      100

      20-60

      single:20¡Á2,

      dual:25

      663

      10¡Á56.5¡Á126 ¡¡

      ibid

      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GDMPG(50)-1/2

      6-12/24

      <1.0

      60

      20-50

      single:35¡Á2

      dual:50

      759

      110¡Á70¡Á126

      ¡¡

      Structure>>here

      ¡¡

      GDMPG(35)-3/4

      6-12/24

      <1.0

      -50-60

      20-50

      single:25¡Á2

      dual:50

      759

      110¡Á70¡Á126

      ¡¡

      Structure>>here

      ¡¡

      ¡¡

      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

      Name and model

      Voltage

      (V)

      No-load Current

      £¨A£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      GFMPE-1/2 12/24 <0.67/0.35 -- ¡Ö60 Four:5-18 375 45¡Á64.5¡Á124

      Structure>>here

      GFMPE-3/4

      12/24

      <0.67/0.35.67¡¡

      --

      ¡Ö45

      Four:3-15

      375 45¡Á64.5¡Á124 ¡¡ ¡¡
      Other ¡¡ ¡¡ ¡¡ ¡¡ Four:1-10 375 45¡Á64.5¡Á124 ¡¡ ¡¡
      ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

      HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

      Name and model

      Voltage

      (V)

      No-load Current

      £¨mA£©

      Pressure

      (kPa)

      Vacum

      (kPa)

      Intake Flow

      L/min

      Weight(g)

      Pump Size

      Structure of the show

      reference Figure

      HLA-2

      ¡¡

      --

      ¡¡ ¡¡ 50mL and 100mL two tranches. ¡¡ ¡¡